One of the fastest and most powerful leak testers on the market, the Vector leak tester line raises performance to new levels of efficiency and productivity. Their unrivalled speeds enable you to conduct leak and flow tests faster, increasing production like never before.
Count on Vector leak testers to deliver the utmost in accuracy and repeatability while eliminating false rejects and keeping defective products from reaching the market. Vector software runs in a Windows® 10 environment making it extremely powerful yet very simple to use.
Vector leak testers are available in bench top, 3U and 6U formats, all featuring Uson engineered pneumatic circuits optimized for specific leak and flow testing applications. The Vector’s modular design lets you expand your system’s capabilities as needed. A single Vector leak tester can perform up to 10 independent or concurrent tests. In addition to supporting unlimited types of leak and flow tests, the unique flexibility of Vector software allows you to add or modify functionality as future requirements dictate.
Vector LT | Notes | |
|
|
|
Max Channels - Design | 10 |
Vector LT | Notes | |
Synchronous | Test multiple parts or chambers concurrently. | |
Independent | Test parts or chambers in sequence | |
Coordinated |
Vector LT | Notes | |
Compressed Air | ||
Helium | ||
Nitrogen |
Vector LT | Notes | |
Max Decision Sensors / tester | 20 | 0 to 5 VDC max |
Max Sensors / channel | 2 | |
A/D resolution (bits) | 24 | High resolution for greater accuracy. |
Max Analog Outputs / tester | 10 | 0 to 10 VDC |
Max Analog Outputs / channel | 1 | |
Analog Output bits | 12 | Pulse width modulation (PWM) |
Maximum 24V DC discrete digital inputs / tester | 72 | |
Valve Control signals / tester | 8 / channel | Requires additional relays to drive valves |
Maximum 24V DC discrete digital outputs / tester | 112 | Vector can send outputs to PLC for decision making |
Discrete digital outputs / channel | 8 | |
Standard configurable digital I/O | Assign inputs and outputs for custom automation. | |
Digital I/O Expansion option | 16 in/16 out 32 in/32 out and requires relays for valves | Requires 1 or 2 additional cPCI cards. |
Two-handed start support (software based) | Valuable safety feature for semi auomate systems. | |
Digital I/O Voltage Level | 24 vdc |
Vector LT | Notes | |
RS-232 ports / tester | 12 | 2 on main CPU, and one per channel. |
Host USB 2.0 ports | 3 | |
Profibus | Supports the most common communication protocols | |
Modbus Serial | ||
Modbus Ethernet TCPIP | ||
Devicenet | ||
Ethernet IP | ||
Profinet |
Vector LT | Notes | |
RJ 45 Ethernet ports | 2 | Connect to a network. |
Logging to a networked disk | Log data to a remote computer. |
Vector LT | Notes | |
Size (H*W*D) Inches | *14x22x20.5 | * HMI Only |
Weight lbs | 65 | |
Color Display size | 12.1" | |
Color Display pixels | 800 x 600 | |
Front-panel membrane buttons | 29 | Full operator control from front panel if desired. |
Front-panel run / program key | ||
Front panel start/abort buttons | ||
NEMA 12 | Indoor protection against common non corrosive liquids and dust. | |
Remote pneumatics chassis | Most comprehensively configurable pneumatics. | |
Test Ports | Custom | Choice of number and locations. |
Calibration Ports | Custom | Choice of locations. |
Test port style | Per Design | |
Built-in AC or DC power supply | ||
Pendant Style Remote Control | Remote control via pendant - useful for when the unit is caged or access is controlled. |
Vector LT | Notes | |
Pressure | Supports all common test types as well as electrical and temperature measurements. | |
Mass flow | ||
Differential pressure | ||
Load cell | ||
Laminar flow | ||
LVDT | ||
Electrical current | ||
Electrical volts | ||
Temperature |
Vector LT | Notes | |
Measure | Supports all common test types as well as electrical and temperature measurements. | |
Pressure Decay with optional comp & optional cal from vacuum to 500PSI | ||
Mass Flow with optional comp & optional cal | Limited to practicality | |
Laminar flow | Supports all common test types as well as electrical and temperature measurements. | |
Vacuum decay | ||
Pressure Increase Chamber Test | ||
Sealed component test (a.k.a., Metered Chamber Test) | ||
Occlusion Test | ||
Burst under Pressure | ||
Burst under Vacuum | ||
Crack, upstream | ||
Crack, downstream | ||
Auto Zero | ||
Wait for input | ||
Coarse Flow | ||
Vacuum force decay | ||
Differential Vacuum | ||
Differential Pressure decay; 0 to 15 bar |
Vector LT | Notes | |
Real time clock | ||
Program select via Digital Inputs | Interface easily with PLC | |
Start / Abort via Digital inputs | ||
Bar code input & control | Select programs according to bar code reader. | |
Auto Comp & Auto Cal | Built in calibration mode makes calibration easy. | |
Temp Comp (Pressure change) | Supporst both common methods of temperature compensation. | |
Temp Comp (Temp change) | ||
Q-DAS interface | Limited | |
Regulator – closed loop control | Gain maximum performance from electronically programmed regulators. | |
In-field configuration | Easy to set up and reprogram. | |
Configurable Pressure Units: psig, mbar, inH2O, mmH2O, inHg, mmHg, Kpa or Kg/cm2 | Select units familiar to the locale. | |
Parts Grading | Identify borderline failures for reclaim. | |
Auto Run Mode | Tester wil continue to test automatically until aborted. | |
Conditional Program Jumps | Jump from program to program based upon conditional inputs. | |
Accept/ Reject Step Markers – Continuous with timeout | ||
Accept/ Reject Step Markers - Pulsed |
Vector LT | Notes | |
Accept/ Reject / Total Counts | Wide variety of statistical reports to provide valuable information for SPC and SQC. | |
Min/Max Test Result | ||
Average Pass/Reject Result | ||
Standard Deviation of all test results | ||
Range of test results | ||
Pressure versus time plot |
Vector LT | Notes | |
Operating System Software | Windows 10 | |
Run/Program security key | ||
Password protection | ||
Hard Disk | ||
Addressable programs | Up to 8 programs per group | Actual number of programs is dependent upon number of channels and program sequences - for practical purposes number of program is |
Programs | Unlimited program storage on hard drive | |
Internal Test Result storage (test cycles) | 100,000+ | |
Sequence | Jumps within a test, optional jumping and grading within a channel, conditional wait on input | Program complex tests and base decisions on conditional inputs. |
Sensor Calibration | Software zero & span. | Built in calibration mode makes zero and span simple to perform. |
Step Editing | Create complex tests. |
The complete library of literature for all our products is now online.
Click to download »
8640 N. Eldridge Parkway
Houston, TX 77041 USA
Tel: +1-281-671-2000
Fax: +1-281-671-2001
Email: info@uson.com
Western Way
Bury St. Edmunds
Suffolk, IP33 3SP United Kingdom
Tel: +44-1284-760606
Fax: +44-1284-763049
Email: salesuk@uson.com
Room 601, 567 Lan Gao Road
Shanghai, 200333, China
Main: 021-583 65859, 021-583 59187
Fax: 021-583 59185, 021-337 73559
Email: sales@uson.com.cn
Copyright © 2022 Uson, L.P. All rights reserved.