Uson Leak Tester Specifications

Raptor Sprint iQ Qualitek mR Optima vT Vector Notes
Product Raptor Sprint iQ Qualitek mR Optima vT Vector
Industries Best Suited for Use
  • Industrial
  • Packaging
  • Medical
  • Automotive
Max Channels-Design 1 4 1 2 10

Channel Operating Modes

Raptor Sprint iQ Qualitek mR Optima vT Vector Notes
Synchronous
Independent
Coordinated

Inputs/Outputs

Raptor Sprint iQ Qualitek mR Optima vT Vector Notes
Max Decision Sensors / tester 1 4 3 8 20 0 to 5 VDC max
Max Sensors / channel 1 1 2 4 2+1
A/D resolution (bits) 24 24 24 24 24
Max Analog Outputs / tester 1 1 2 10 0 to 10 VDC
Max Analog Outputs / channel 1 1 1 1
Analog Output bits PWM (~12) PWM (~12) 16 12 Pulse width modulation (PWM)
Maximum 24V DC discrete digital inputs / tester 8 11* 11 64 72 * requires PLC interface option
Valve Control signals / tester 2 internal , 5 external, for valve control 18 (Internal) 16 (Internal) 12 / channel 8 / channel Vector requires additional relays to drive valves (0.7A per output - 8A Maximum for Optima vT)
Maximum discrete digital outputs / tester 5 11 (not standard) 5 48 112
Discrete digital outputs / channel 5 2 5 12 8
Standard configurable digital I/O
Digital I/O Expansion option N/A 8 in/16 out requires relays for valves Additional 16 in 12 (valve drive capable) out (per TCU) 16 in/16 out 32 in/32 out and requires relays for valves QmR requires additional PCB, vT requires Expanded I/O TCU2 Vector requires 1 or 2 addisional cPCI cards.
Two-handed start support (software based)
Digital I/O Voltage Level 24 vdc 24 vdc 24 vdc 24 vdc 24 vdc

Communication Interfaces

Raptor Sprint iQ Qualitek mR Optima vT Vector Notes
RS-232 ports / tester 1 1 4 12 vT and Vector have 2 on main CPU, vT and Vector have one per channel. Channel ports currently not firmware implemented.
Host USB 2.0 ports 1 2 2 5 3
Device USB ports 1 1
Profibus
Modbus Serial
Modbus Ethernet
Ethernet IP
DeviceNet

Local Area Network Support

Raptor Sprint iQ Qualitek mR Optima vT Vector Notes
RJ 45 Ethernet ports 1 1 1 2 2
Logging to a networked disk iQ via FTP
Emailed alerts

Physical Characteristics

Raptor Sprint iQ Qualitek mR Optima vT Vector Notes
Size (H*W*D) Inches 5.25" H X 7.75" W X 13" D 11 x 9 x 15 7 x 10.75 x 12 *10 x 14 x 5 *14x22x20.5 * HMI Only
Weight lbs 10.5 18 24 15 65
Color Display size 4.3" 5.8" 8.5" 15" 12.1"
Color Display pixels 480 x 272 320 x 240 640 x 480 1024 x 768 800 x 600
Touch screen display
Touch scroll control pad
Front-panel membrane buttons 6 5 5 29
Front-panel run / program key
Front panel start/abort buttons * *vT uses touch screen
NEMA 12
Integrated pneumatics
Expandable pneumatics chassis
Remote pneumatics chassis
Test Ports 1 4 1 Custom Custom
Calibration Ports Combined with Test Ports Combined with Test Ports 1 Custom Custom
Test port style 1/8 NPT Female 1/8 NPT Female 1/8 NPT Female Per Design Per Design
Built-in AC or DC power supply
Pendant Style Remote Control

Sensor Types

Raptor Sprint iQ Qualitek mR Optima vT Vector Notes
Pressure
Mass flow
Differential pressure
Load cell
Laminar flow
LVDT
Electrical current
Electrical volts
Temperature For the QMR the temperature input is exclusively for temperature compensation.

Test Techniques / Step Types

Raptor Sprint iQ Qualitek mR Optima vT Vector Notes
Measure
Pressure Decay with optional comp & optional cal from 0 to 1 500 psi max = 150PSI
Mass Flow with optional comp & optional cal from 0 to 560 slpm iQ limited to 20 slm, QmR limited to 20 slpm, vT/Vector limited to practicality
Laminar flow
Vacuum decay
Pressure Increase Chamber Test
Sealed component test (a.k.a., Metered Chamber Test)
Occlusion Test
Burst under Pressure
Burst under Vacuum
Crack, upstream
Crack, downstream
Auto Zero
Wait for input
Coarse Flow
Vacuum force decay
Differential Vacuum
Differential Pressure decay; 0 to 15 bar

Operational Features

Raptor Sprint iQ Qualitek mR Optima vT Vector Notes
Real time clock
Program select via Digital Inputs
Start / Abort via Digital inputs
Bar code input & control No tester control for Sprint iQ
Auto Comp & Auto Cal
Temp Comp (Pressure change)
Temp Comp (Temp change)
Q-DAS interface Limited
Regulator – closed loop control Fixed Algorithm based *
In-field configuration
Configurable Pressure Units: psig, mbar, inH2O, mmH2O, inHg, mmHg, Kpa or Kg/cm2
Parts Grading
Auto Run Mode
Conditional Program Jumps
Accept/ Reject Step Markers – Continuous with timeout
Accept/ Reject Step Markers - Pulsed

Data: Statistics and Graphical Displays

Raptor Sprint iQ Qualitek mR Optima vT Vector Notes
Accept/ Reject / Total Counts
Min/Max Test Result
Average Pass/Reject Result
Standard Deviation of all test results
Range of test results
Pressure versus time plot

Software

Raptor Sprint iQ Qualitek mR Optima vT Vector Notes
Operating System Software Embedded Unix Based Quadros RTOS Unix Based Unix Based Windows XP
Run/Program security key
Password protection
Hard Disk
R/W DVD (CD) option
Programs 10 99 99 199 TBD
Internal Test Result storage (test cycles) 5000 250 1000 100,000+ 100,000+
Sequence Program link. Stop control, Vent control, Delay time option, Step control Program link. Stop control, Vent control, Delay time option, Step control  Jumps within a test, optional jumping and grading within a channel, conditional wait on input, math steps Jumps within a test, optional jumping and grading within a channel, conditional wait on input
Sensor Calibration Software zero & span. Software zero & span with option of multi-point linearization per analog input. Software zero & span with option of multi-point linearization per analog input. Software zero & span with option of multi-point linearization per analog input. Software zero & span.
Step Editing
Math Steps

Industries

Automotive Automotive
No matter how much auto and auto part... Learn More >

Medical Medical
Whether testing aspirators and cathete... Learn More >

Packaging Packaging
Ideal for the packaging industry, Uso... Learn More >

Industrial Industrial
Advanced features like data collection... Learn More >

Test Methods

There are many different factors that determine which type of leak detection method is best suited for a given application. That is where Uson can really help.

Contact Us

Uson L.P. - Corporate

8640 N. Eldridge Parkway
Houston, TX 77041 USA

Tel: +1-281-671-2000
Fax: +1-281-671-2001

Email: info@uson.com

Uson UK – Europe

Western Way
Bury St. Edmunds
Suffolk, IP33 3SP United Kingdom

Tel: +44-1284-760606
Fax: +44-1284-763049

Email: salesuk@uson.com

Uson – Detroit

31471 Utica Rd
Fraser, MI 48026 USA

Tel: +1-248-589-3100
Fax: +1-248-589-3103

Email: Michigan@uson.com

Uson – China

Room 601, 567 Lan Gao Road
Shanghai, 200333, China

Main: 021-583 65859, 021-583 59187
Fax: 021-583 59185, 021-337 73559

Email: sales@uson.com.cn